Nylon resins are typically used in applications requiring heat and chemical resistance, as well as, toughness. Some examples include under-the-hood automotive components, electrical connectors for the telecommunications and computer industries and components of medical devices. Nylon products can be found in virtually every industry. Parts in a broad range of colors can be produced with most nylon resins.

Ultramid® AZ3 (Polyamide [nylon66]) Property Sheet -- Dry and Cond.

*  All Values are Nominal.
Physical Dry Cond. Test
Density-Specific Gravity 1.07 sp gr 23/23 ºC 1.07 sp gr 23/23 ºC ASTM D792
Mold Shrink, Linear-Flow 16 mil/in -- ASTM D955
Water Absorption @ 24 hrs 2.3 % 2.3 % ASTM D570
Water Absorption @ Equil 7.2 % 7.2 % ASTM D570

Mechanical Dry Cond. Test
Tensile Modulus 3.13e+005 psi 1.1e+005 psi ASTM D638
Tensile Strength @ Yld 7900 psi -- ASTM D638

Impact Dry Cond. Test
Notched Izod Impact:
(73 ºF)
(-40 ºF)
 
17 ft-lb/in
3 ft/lb/in
 
No Break
--
ASTM D256

Thermal Dry Cond. Test
DTUL @ 264psi - Unannealed 140 ºF -- ASTM D648
DTUL @ 66psi - Unannealed 340 ºF -- ASTM D648
Melting Point 500 ºF 500 ºF --
CLTE, Flow 4.5e-005 in/in/ºF -- ASTM D696

Electrical Dry Cond. Test
Surface Resistivity 1e+013 ohms 1e+012 ohms ASTM D257
Volume Resistivity 4e+014 ohm-cm 1e+012 ohm-cm ASTM D257
Dielectric Strength 2250 V/mil 1300 V/mil ASTM D149
Dielectric Constant (1e+006 Hz) 3.1 3.6 ASTM D150
Dissipation Factor (1e+006 Hz) .016 .07 ASTM D150
Arc Resistance (.1228 in) 90 sec -- ASTM D495

Ignition Characteristics Dry Cond. Test
Flame Rating - UL:
(.0311 in)
(.05905 in)
(.06102 in, REG)
(.1181 in)
(.1228 in, REG)
 
HB
HB
HB
HB
HB
 
--
--
--
--
--
UL 94
Flame Rating - UL (.0625 in) -- HB UL 94

UL 746 Dry Cond. Test
Rel Temp Index Mech w/o Imp:
(.02952 in)
(.0311 in)
(.05905 in)
(.06102 in)
(.1181 in)
(.1228 in)
 
149 ºF
149 ºF
149 ºF
149 ºF
149 ºF
149 ºF
 
--
--
--
--
--
--
UL 746
Rel Temp Index Mech w/ Imp:
(.02952 in)
(.0311 in)
(.05905 in)
(.06102 in)
(.1181 in)
(.1228 in)
 
149 ºF
149 ºF
149 ºF
149 ºF
149 ºF
149 ºF
 
--
--
--
--
--
--
UL 746
Rel Temp Index Elect:
(.02952 in)
(.0311 in)
(.05905 in)
(.06102 in)
(.1181 in)
(.1228 in)
 
149 ºF
149 ºF
149 ºF
149 ºF
149 ºF
149 ºF
 
--
--
--
--
--
--
UL 746
UL 746 (Cont'd) Dry Cond. Test
Comparative Track Index:
(.0625 in)
(.1228 in)
 
--
600 V
 
600 V
--
UL 746
High Volt Arc Track Rate:
(.1228 in)
 
.1968 in/min
 
--
UL 746
Hot Wire Ignition:
(.06102 in)
 
22.5 sec
 
--
UL 746
High Ampere Arc Ignition:
(.06102 in)
 
120
 
--
UL 746

** These are typical property values intended only as guides. They should not be used to establish specification limits or as the sole basis of design. Determining whether this information, or this plastic, should be used for a particular application is the responsibility of the user.