In-House
Tooling

Materials

Conversion Charts

Online Forms

Quote Request

Bagging

Uni-Screw in Plastic

Track Your Order
 




Back to VIP Home Page Contact VIP Our Team About VIP Product Catalog New Products Event Calendar
Nylon

Printer Friendly Version


Nylon resins are typically used in applications requiring heat and chemical resistance, as well as, toughness. Some examples include under-the-hood automotive components, electrical connectors for the telecommunications and computer industries and components of medical devices. Nylon products can be found in virtually every industry. Parts in a broad range of colors can be produced with most nylon resins.


Vydyne® 20N (Polyamide [nylon66]) Property Sheet -- Dry and Cond.

*  All Values are Nominal.
Physical Dry Cond. Test
Density-Specific Gravity 1.14 sp gr 23/23 ºC -- ASTM D792
Mold Shrink, Linear-Flow 8 to 12 mil/in -- ASTM D955
Water Absorption @ 24 hrs 1.11 % -- ASTM D570
Water Absorption @ Equil 2.5 % -- ASTM D570

Mechanical Dry Cond. Test
Tensile Strength @ Yld 13700 psi 10400 psi ASTM D638
Tensile Elongation @ Yld 10 % 25 % ASTM D638
Tensile Elongation @ Brk 30 % 35 % ASTM D638
Flexural Modulus 4.5e+005 psi 4.5e+005 psi ASTM D790
Flexural Strength @ Yld 16800 psi 9600 psi ASTM D790
Compressive Strength 5000 psi -- ASTM D695
Shear Strength 10000 psi -- ASTM D732

Impact Dry Cond. Test
Notched Izod Impact:(.125 in) .9 ft-lb/in 2.8 ft-lb/in ASTM D256
Tensile Impact Strength  70 ft-lb/in2 100 ft-lb/in2 ASTM D1822

Hardness Dry Cond. Test
Rockwell Hardness:
(M-Scale)
(R-Scale)
 
  88
121
 
  69
113
ASTM D785

Thermal Dry Cond. Test
DTUL @ 264psi - Unannealed  221 ºF 181 ºF ASTM D648
DTUL @ 66psi - Unannealed  478 ºF 457 ºF ASTM D648
Brittle Temperature -100 ºF  -90 ºF ASTM D746
Melting Point  500 ºF  -- --
CLTE, Flow  4.5e-005 in/in/ºF  -- ASTM D696
Thermal Conductivity  1.7 BTU-in/hr/ft2/ºF  -- ASTM C177

Electrical Dry Cond. Test
Volume Resistivity 2e+016 ohm-cm 7e+012 ohm-cm ASTM D257
Dielectric Strength 550 V/mil 545 V/mil ASTM D149
Dielectric Constant:
(100 Hz)
(1000 Hz)
 
3.7
3.6
 
7
6.1
ASTM D150
Dissipation Factor:
(100 Hz)
(1e+006 Hz)
 
.01
.01
 
.11
.09
ASTM D150
Arc Resistance (.125 in) 123 sec -- ASTM D495

Ignition Characteristics Dry Cond. Test
Flame Rating - UL:
(.03125 in)
(.0625 in)
(.125 in)
 
V-2
V-2
V-2
 
--
--
--
UL 94
Limiting Oxygen Index 25.5 % 35 % ASTM D2863

UL 746 Dry Cond. Test
Rel Temp Index Mech w/o Imp:
(.03125 in)
(.0625 in)
(.125 in)
 
185 ºF
185 ºF
185 ºF
 
--
--
--
UL 746
Rel Temp Index Mech w/ Imp:
(.03125 in)
(.0625 in)
(.125 in)
 
167 ºF
167 ºF
167 ºF
 
--
--
--
UL 746
Rel Temp Index Elect:
(.03125 in)
(.0625 in)
(.125 in)
 
266 ºF
266 ºF
266 ºF
 
--
--
--
UL 746
UL 746 (Cont'd) Dry Cond. Test
Comparative Track Index:
(.125 in)
 
600 V
 
--
UL 746
High Volt Arc Track Rate:
(.0625 in)
(.125 in)
 
.2 in/min
.5 in/min
 
--
--
UL 746
Hot Wire Ignition:
(.03125 in)
(.0625 in)
(.125 in)
 
12 sec
15 sec
32 sec
 
--
--
--
UL 746
High Ampere Arc Ignition:
(.03125 in)
(.0625 in)
(.125 in)
 
200
200
200
 
--
--
--
UL 746

** These are typical property values intended only as guides. They should not be used to establish specification limits or as the sole basis of design. Determining whether this information, or this plastic, should be used for a particular application is the responsibility of the user.