Nylon resins are typically used in applications requiring heat and chemical resistance, as well as, toughness. Some examples include under-the-hood automotive components, electrical connectors for the telecommunications and computer industries and components of medical devices. Nylon products can be found in virtually every industry. Parts in a broad range of colors can be produced with most nylon resins.


Vydyne® 22HSP (Polyamide [nylon66]) Property Sheet -- Dry and Cond.

*  All Values are Nominal.
Physical Dry Cond. Test
Density-Specific Gravity 1.14 sp gr 23/23 ºC -- ASTM D792
Mold Shrink, Linear-Flow 15 to 20 mil/in -- ASTM D955
Water Absorption @ 24 hrs 1.4 % -- ASTM D570

Mechanical Dry Cond. Test
Tensile Strength @ Yld 12400 psi 9500 psi ASTM D638
Tensile Elongation @ Yld 10 % 25 % ASTM D638
Tensile Elongation @ Brk 70 % 200 % ASTM D638
Flexural Strength @ Yld 15200 psi 8100 psi ASTM D790

Impact Dry Cond. Test
Notched Izod Impact:
(73ºF, .125 in)
(-40ºF, .125 in)
 
.9 ft-lb/in
.6 ft/lb/in
 
 2.7 ft-lb/in
.5 ft/lb/in
ASTM D256
Tensile Impact Strength:
(73ºF)
 
 75 ft-lb/in2
 
 --
ASTM D1822

Hardness Dry Cond. Test
Rockwell Hardness:
(M-Scale)
(R-Scale)
 
  88
119
 
  61
108
ASTM D785

Thermal Dry Cond. Test
DTUL @ 264psi - Unannealed 190 ºF 165 ºF ASTM D648
DTUL @ 66psi - Unannealed 450 ºF 430 ºF ASTM D648
Melting Point 500 ºF -- --
CLTE, Flow 4.5e-005 in/in/ºF -- ASTM D696
Thermal Conductivity 1.7 BTU-in/hr/ft2/ºF -- ASTM C177

Electrical Dry Cond. Test
Volume Resistivity 3.6e+015 ohm-cm 1.4e+013 ohm-cm ASTM D257
Dielectric Strength 536 V/mil 568 V/mil ASTM D149
Dielectric Constant:
(100 Hz)
(1000 Hz)
 
3.6
3.6
 
7.4
5.9
ASTM D150
Dissipation Factor:
(100 Hz)
(1000 Hz)
 
.008
.013
 
.19
.14
ASTM D150

Ignition Characteristics Dry Cond. Test
Flame Rating - UL (.028 in) V-2 -- UL 94