| Physical |
Dry |
Cond. |
Test |
| Density-Specific
Gravity |
1.47 sp
gr 23/23 ºC |
-- |
ASTM D792 |
| Mold Shrink,
Linear-Flow |
2 to 6
mil/in |
-- |
ASTM D955 |
| Water Absorption
@ 24 hrs |
.7 % |
-- |
ASTM D570 |
|
| Mechanical |
Dry |
Cond. |
Test |
| Tensile
Strength @ Yld |
16500 psi |
12500 psi |
ASTM D638 |
| Tensile
Elongation @ Yld |
7 % |
7 % |
ASTM D638 |
| Tensile
Elongation @ Brk |
7 % |
7 % |
ASTM D638 |
| Flexural
Modulus |
1.05e+006
psi |
7e+005
psi |
ASTM D790 |
| Flexural
Strength @ Yld |
28000 psi |
20000 psi |
ASTM D790 |
|
| Impact |
Dry |
Cond. |
Test |
Notched
Izod Impact:
(73ºF, .125 in)
(-40ºF, .125 in) |
1.9 ft-lb/in
1.4 ft/lb/in |
2.4 ft-lb/in
-- |
ASTM
D256 |
|
| Hardness |
Dry |
Cond. |
Test |
Rockwell
Hardness:
(M-Scale)
(R-Scale) |
89
120 |
70
110 |
ASTM
D785 |
|
| Thermal |
Dry |
Cond. |
Test |
| DTUL @
264psi - Unannealed |
464 ºF |
460 ºF |
ASTM D648 |
| Melting
Point |
482 ºF |
-- |
-- |
| CLTE, Flow |
1.7e-005
in/in/ºF |
3.1e-005
in/in/ºF |
ASTM D696 |
| Thermal
Conductivity |
2.4 BTU-in/hr/ft2/ºF |
-- |
ASTM C177 |
|
| Electrical |
Dry |
Cond. |
Test |
| Volume
Resistivity |
3.8e+012
ohm-cm |
8e+012
ohm-cm |
ASTM
D257 |
| Dielectric
Strength |
540 V/mil |
450 V/mil |
ASTM
D149 |
Dielectric
Constant:
(100 Hz)
(1000 Hz) |
4
3.9 |
5.9
5 |
ASTM
D150 |
Dissipation
Factor:
(100 Hz)
(1000 Hz) |
.13
.15 |
.03
.3 |
ASTM
D150 |
|
| Ignition
Characteristics |
Dry |
Cond. |
Test |
Flame Rating
- UL:
(.031 in)
(.062 in)
(.12 in) |
V-0
V-0
V-0 |
--
--
-- |
UL
94 |
| Limiting
Oxygen Index |
34 % |
34 % |
ASTM D2863 |
|
| UL 746 |
Dry |
Cond. |
Test |
Rel Temp
Index Mech w/o Imp:
(.031 in)
(.062 in)
(.12 in) |
230 ºF
230 ºF
230 ºF |
--
--
-- |
UL
746 |
Rel Temp
Index Mech w/ Imp:
(.031 in)
(.062 in)
(.12 in) |
149 ºF
203 ºF
203 ºF |
--
--
-- |
UL
746 |
Rel Temp
Index Elect:
(.031 in)
(.062 in)
(.12 in) |
266 ºF
266 ºF
266 ºF |
--
--
-- |
UL
746 |
** These
are typical property values intended only as guides. They
should not be used to establish specification limits or as
the sole basis of design. Determining whether this information,
or this plastic, should be used for a particular application
is the responsibility of the user. |